Регистры Allwinner H616

Сокращения  |  Дерево шин  |  Карта памяти


TWI_STAT
9.1.5. TWI Status Register - адрес: 0x5002010 0x5002410 0x5002810 0x5002c10 0x5003010 0x7081410 (смещение: 0x0010)

Двухпроводной интерфейс: список регистров



31 ||||||||||||||||| 16
15 ||||||||||||||||| 00

  Unused

Bits 31 : 8

  STA

Bits 7 : 0
R
0xF8

Status Information Byte
Code Status
0x00: Bus error
0x08: START condition transmitted
0x10: Repeated START condition transmitted
0x18: Address + Write bit transmitted, ACK received
0x20: Address + Write bit transmitted, ACK not received
0x28: Data byte transmitted in master mode, ACK received
0x30: Data byte transmitted in master mode, ACK not received
0x38: Arbitration lost in address or data byte
0x40: Address + Read bit transmitted, ACK received
0x48: Address + Read bit transmitted, ACK not received
0x50: Data byte received in master mode, ACK transmitted
0x58: Data byte received in master mode, not ACK transmitted
0x60: Slave address + Write bit received, ACK transmitted
0x68: Arbitration lost in address as master, slave address + Write bit received, ACK transmitted
0x70: General Call address received, ACK transmitted
0x78: Arbitration lost in address as master, General Call address received, ACK transmitted
0x80: Data byte received after slave address received, ACK transmitted
0x88: Data byte received after slave address received, not ACK transmitted
0x90: Data byte received after General Call received, ACK transmitted
0x98: Data byte received after General Call received, not ACK transmitted
0xA0: STOP or repeated START condition received in slave mode
0xA8: Slave address + Read bit received, ACK transmitted
0xB0: Arbitration lost in address as master, slave address + Read bit received, ACK transmitted
0xB8: Data byte transmitted in slave mode, ACK received
0xC0: Data byte transmitted in slave mode, ACK not received
0xC8: Last byte transmitted in slave mode, ACK received
0xD0: Second Address byte + Write bit transmitted, ACK received
0xD8: Second Address byte + Write bit transmitted, ACK not received
0xF8: No relevant status information, INT_FLAG=0
Others: Reserved



Команда U-Boot для чтения регистра

md 5002010 1
md 5002410 1
md 5002810 1
md 5002c10 1
md 5003010 1
md 7081410 1



Bit fields structure

typedef union  twi_stat
{
  struct
  {
   unsigned sta : 8;
   unsigned unused0 : 24;
  } b;
   unsigned long w;
} TWI_STAT
   