These common errors may occur in various PCP interactions.
PM_ERR_TIMEOUT
Timeout waiting for a response from PMCD
Many interactions between PCP applications involve
synchronous message passing, and these are subject to timeout
constraints. These errors are most frequently encountered
when using network connections with slow data rates or long
latencies.
For client-pmcd
timeouts, refer to PCPIntro(1) for
environment variables that may be used to modify the timeout
thresholds. For pmcd
-PMDA timeouts refer to the -t
and -q
options of pmcd(1) and the PCP metric pmcd.control.timeout
that can be dynamically changed with pmstore(1).
PM_ERR_APPVERSION
Metric not supported by this version of monitored application
Some performance metrics are unavailable from specific
versions of the associated PMDA, or may be unavailable
because the underlying instrumentation has changed or is not
installed or is not enabled. This error is used in results
from pmFetch(3) to indicate these situations.
PM_ERR_IPC
IPC protocol failure
Generic protocol failure on a pipe or socket connecting two
PCP applications, eg. client-pmcd
, or client-pmtime
, or
PMDA-pmcd
or pmlc
-pmlogger
.
PM_ERR_TEXT
One-line or help text is not available
Set by a PMDA, and passed back to a PCP client, to indicate
that the PMDA is unable to supply the requested metric or
instance domain help text.
PM_ERR_VALUE
Missing metric value(s)
This error is used for a number of conditions in which the
value of a performance metric is inappropriate for the
context in which it is being used, eg.
(a) Bad value for the metric pmcd.timezone
when trying to set
the timezone via pmNewContextZone(3) for a remote or
archive context.
(b) Attempting to interpolate values for a metric with non-
numeric data type from a set of PCP archives.
(c) A bad result data structure passed to pmStore(3).
PM_ERR_NAME
Unknown metric name
Just what the message says.
PM_ERR_PMID
Unknown or illegal metric identifier
Just what the message says.
PM_ERR_INDOM
Unknown or illegal instance domain identifier
A request nominates an instance domain that is unknown or
PM_INDOM_NULL
. May occur as a consequence of the instance
domain identifier passed by a PCP client to pmGetInDom(3),
pmLookupInDom(3), pmNameInDom(3), pmGetInDomArchive(3),
pmLookupInDomArchive(3), pmNameInDomArchive(3) or a request
passed from pmcd(1) to a PMDA.
PM_ERR_EOF
IPC channel closed
End of file on a pipe or socket connecting two PCP
applications, eg. client-pmcd
, or client-pmtime
or PMDA-pmcd.
PM_ERR_NOCONTEXT
Attempt to use an illegal context
Typically caused by a PCP client that tries to make calls
before calling pmNewContext(3) or after calling
pmDestroyContext(3).
PM_ERR_PERMISSION
No permission to perform requested operation
PCP-specific access controls apply to pmcd(1) and
pmlogger(1). Platform-specific permission errors are
returned as -EPERM
.
PM_ERR_CONV
Impossible value or scale conversion
Some value conversion requests are illegal, eg. bad debug
flag symbolic name for -D/--debug
option, or asking
pmExtractValue(3) to translate non-numeric data types to
numbers and vice versa.
PM_ERR_TRUNC
Truncation in value conversion
Some conversion requests to pmExtractValue(3) cannot be
performed based on the metric types and values involved, in
this case conversion would result in loss of precision.
PM_ERR_SIGN
Negative value in conversion to unsigned
Some conversion requests to pmExtractValue(3) cannot be
performed based on the metric types and values involved, in
this case converting a negative value to an unsigned value.
PM_ERR_TYPE
Unknown or illegal metric type
The metric type is held in the metric descriptor and
sometimes encoded in the metric values returned from a call
to pmFetch(3). Legal values for the metric type are defined
by the PM_TYPE_*
macros in <pcp/pmapi.h>
.
PM_ERR_UNIT
Illegal pmUnits specification
Some conversion requests to pmConvScale(3) cannot be
performed due to illegal or incompatible specifications of
the source and destination units.
PM_ERR_PROFILE
Explicit instance identifier(s) required
Some PMDAs, especially the proc
PMDA, will not return ``all
instances'' for a pmFetch(3) request due to the cost. The
client must explicitly built an instance profile using
pmAddProfile(3) and/or pmDelProfile(3) before calling
pmFetch(3). See also the -F/--fetchall
option to pminfo(1).
PM_ERR_INST
Unknown or illegal instance identifier
A request to a PMDA nominates an instance that is unknown.
May occur as a consequence of the profile established prior
to a pmFetch(3) call, or an explicit instance name or
identifier to pmLookupInDom(3) or pmNameInDom(3).
PM_ERR_MODE
Illegal mode specification
Illegal mode argument to pmSetMode(3).
PM_ERR_PROFILESPEC
NULL pmInDom with non-NULL instlist
Bad arguments passed from a PCP client to pmAddProfile(3).
PM_ERR_TOOSMALL
Insufficient elements in list
Parameter passing error by caller specifying a list with less
than one element to pmFetch(3), pmLookupName(3) or
pmStore(3).
PM_ERR_FAULT
QA fault injected
For testing, there is a ``fault injection'' version of libpcp
and this error indicates a misuse of the fault injection
infrastructure.
PM_ERR_THREAD
Operation not supported for multi-threaded applications
As documented in PMAPI(3) and elsewhere, some libpcp
routines
are intended solely for use from single-threaded
applications.
PM_ERR_NOCONTAINER
Container not found The user supplied container name does not
match any known container.
PM_ERR_BADSTORE
Bad input to pmstore
The metric value provided for a pmStore(3) operation is in
the wrong format, or of the wrong type or has the wrong
number of values.
PM_ERR_TOOBIG
Result size exceeded
Indicates a fatal error in the message (or PDU) passing
protocol between two PCP applications. This is an internal
error, and other than an exotic networking failure, should
not occur.
PM_ERR_RESET
PMCD reset or configuration change
Not used.
Refer to pmFetch(3) for an alternative mechanism that may be
used to notify a PCP client when pmcd(1) has experienced one
or more configuration changes since the last request from the
client. Usually these changes involve a change to the
namespace exported via pmcd
and/or changes to the PMDAs under
pmcd
's control.
PM_ERR_FAULT
QA fault injected
Used only for PCP Quality Assurance (QA) testing.
PM_ERR_NYI
Functionality not yet implemented
Self explanatory and rarely used.
PM_ERR_GENERIC
Generic error, already reported above
Rarely used, this error may be returned when the error
condition is a consequent of some earlier returned error and
a more precise characterization is not possible.
PM_ERR_BADDERIVE
Derived metric definition failed
When registering a derived metric, the metric expression is
either syntactically or semantically incorrect.
PM_ERR_NOLABELS
No support for metric label metadata
Operation requires metric labels, but none are available.